Alloy SH 310 may be welded with most of the welding processes. This includes :
                                      TIG, PLASMA, MIG Weldings as well as SMAW, SAW and FCAW processes. Use
           WELDING                    AWS/ASME E310-15 (AWS A-5-4 or ASME SFA5-4) electrodes or AWS/ASME ER
                                      310  wires  while  for  the  final  passes  AWS/ASME  E309-15  (AWS  A-5-9  or  ASME
                                      SF5-9) electrodes or AWS/ASME ER 309  wires  are recommended.
                                      The  best  toughness  results  will  be  obtained  with  basic  fluxes  when  considering
                                      weldings with SAW method of flux cored electrodes or argon as shielding gases.
                                      Interpass temperature is limited at 150°C (302°F).
                                      Usual  precautions  for  stainless  steels  including  cleaning  and  degreasing  of  weld
                                      areas,  protection  against  weld  spatters  must  be  taken.  Grind  the  start  and  the
                                      finish of each filler pass before to start with next filler  pass.
                                      Mechanical  methods  including  grinding  and  polishing  will  be  used  to    remove
                                      oxide,  slag  incrustations,  heat  tint  or  other  surface  contamination.  Etching  with
                                      pastes are also allowed but avoid overetching


                                       Furnaces : burners, heat recupertors, doors, circulating fans and pipings... for
                                         the most critical conditions.
                                       Pyrometallurgy : smelter and steel melting equipments, rollers for continuous
         APPLICATIONS                    casting equipments...
                                       Heat treatment furnaces : walking beams, doors, burners grids, heat
                                         recuperators including for nitriding and cementary gases
                                       Sintering or cement plants : feeding and discharging systems, burners and
                                         burners shield, wind boxes...
                                       On/Offshore - Refineries : candelabra, catalytic recovery systems,
                                         recuperators...
                                       Fluidised bed furnaces : grids, wind boxes, pipings...



                                                                                                  Clad plates
                                          Thickness     Hot rolled plates   Cold rolled plates   6 to 150 mm
                                                          5 to 150 mm
                                                                              2 to 14 mm
                                                                                                   1/4" to 6"
                                                                              5/64" to 5/8"
                                                           3/16" to 6"
         SIZE RANGE                                      Up to 3300 mm       Up to 2300 mm       Up to 3300 mm
                                           Width
                                                           Up to 130"         Up to 90.5"         Up to 130"
                                                        Up to 12000 mm       Up to 8250 mm      Up to 14000 mm
                                           Length          Up to 472"         Up to 325"          Up to 551"
                                      Other sizes are available on request, including 4100mm (161,4") width plates


                                      NOTE
                                      This technical data and information represents our best knowledge at the time of printing. However, it may
                                      be subject to some slight variations due to our ongoing research programme on corrosion resistant grades.
                                      We therefore suggest that information be verified at time of enquiry or order.
                                      Furthermore, in service, real conditions are specific for each application. The data presented here is only for
                                      the purpose of description, and may only be considered as guarantees when our company has given written
                                      formal approval.
                                      Further information may be obtained from the following address.
   1   2   3   4